CPX Medical Gas Outlets Plastic DIN Standard

CPX DIN Medical Gas Outlets are manufactured and designed in our UK factory, with full metal construction, Gas Indexing as EN 13260-2, EN 9170, and Medical Gas Pipelines EN 7396, DIN 13260-2 Part 2: Dimensions and allocation of probes and gas-specific connection points for Terminal Units. CPX DIN Gas Outlets are available for wall mounting (Flush or Surface), Bed Head trunking, and Pendant mounting. Can be supplied with metal or plastic second fix.

Medical Degreased Copper Fittings

CPX End Feed Copper Fittings are manufactured in the UK to the requirements of BS EN 13485 – Medical Devices: Quality Management Systems and are purpose-built for critical medical pipeline installations. Engineered for compatibility with degreased medical copper tube systems, our fittings are suitable for pipelines compliant with:
  • BS EN 13348
  • BS EN 1057
  • BS 2871 Part 1 Table X – as referenced in HTM 02-01 and C11.
CPX Copper Fittings are produced to meet the specific demands of the medical gas industry. Every aspect—from design and cleanliness to packaging and usability—is carefully considered to support safe, efficient installations that comply fully with HTM 02-01, C11, and BS EN ISO 7396. CPX Degreased Medical Gas Copper Fittings are available in the following variations:
  • Equal Tee
  • 90° Elbow
  • 45° Elbow
  • Straight Coupling
  • Reducing Tees
  • Reducing Coupling
  • End Caps
  • Fitting Reducers
  • Street Elbows

Medical Grade pure silicone tube autoclavable

Gas Specificity Flowmeters shall be supplied with gas-specific probes and only attach to the corresponding Medical Gas Terminal Unit, it accurately measures flow at 0-15Lpm even at variant inlet pressures. Accuracy is fulfilled within 10% to attain maximum efficiency for the patient and environment. Each flow meter is calibrated at 50 psi inlet pressure Materials The Flowmeter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and constructed from a chromium-plated brass body, inner and external tube in crack-resistant polycarbonate and stainless steel ball. Other pieces shall be in brass. Humidifier: Constructed from polycarbonate, sterilisation should be conducted in an autoclave on a 25 min cycle at 121 ºC, 1.3 kPa (max. 40 times). Before sterilisation remove the tube and diffuser and consequently disposed. Quality: Manufactured under BS EN 13485 Medical Devices: Quality Management Systems.  

Product Code Type
FLOW-O2-15 Flow Meter Oxygen – 15l/min & Humidifier
HUMIDIFIER Humidifier Bottle with Lid – 150ml

One Piece ECG Cable with Leads

One Piece ECG Cable with 3 Leads, Pinch  

, ,

Oxygen Outlet Points

CPX DIN Medical Gas Outlets are manufactured and designed in our UK factory, with full metal construction, Gas Indexing as EN 13260-2, EN 9170, and Medical Gas Pipelines EN 7396, DIN 13260-2 Part 2: Dimensions and allocation of probes and gas-specific connection points for Terminal Units. CPX DIN Gas Outlets are available for wall mounting (Flush or Surface), Bed Head trunking, and Pendant mounting. Can be supplied with metal or plastic second fix.

,

PUR Coated Flooring Mattes

CPX DIN Medical Gas Outlets are manufactured and designed in our UK factory, with full metal construction, Gas Indexing as EN 13260-2, EN 9170, and Medical Gas Pipelines EN 7396, DIN 13260-2 Part 2: Dimensions and allocation of probes and gas-specific connection points for Terminal Units. CPX DIN Gas Outlets are available for wall mounting (Flush or Surface), Bed Head trunking, and Pendant mounting. Can be supplied with metal or plastic second fix.

SPO2 Sensor Cable

Reusab;le SPO2 sensor cable.

Wallmounted Oxygen Flowmeter

Gas Specificity Flowmeters shall be supplied with gas-specific probes and only attach to the corresponding Medical Gas Terminal Unit, it accurately measures flow at 0-15Lpm even at variant inlet pressures. Accuracy is fulfilled within 10% to attain maximum efficiency for the patient and environment. Each flow meter is calibrated at 50 psi inlet pressure Materials The Flowmeter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and constructed from a chromium-plated brass body, inner and external tube in crack-resistant polycarbonate and stainless steel ball. Other pieces shall be in brass. Humidifier: Constructed from polycarbonate, sterilisation should be conducted in an autoclave on a 25 min cycle at 121 ºC, 1.3 kPa (max. 40 times). Before sterilisation remove the tube and diffuser and consequently disposed. Quality: Manufactured under BS EN 13485 Medical Devices: Quality Management Systems.  

Product Code Type
FLOW-O2-15 Flow Meter Oxygen – 15l/min & Humidifier
HUMIDIFIER Humidifier Bottle with Lid – 150ml